507
10.2.2.3 Operator config data
An operator connected to the device via the diagnostic interface requires (for optimal op-
eration) information about the characteristics of the diagnostic interface and the object
directory.
These are provided via the structure de10 "Operator config data“.
de10
operator cfg data
0x200A
Subidx
Meaning
Note
0
Structure length
byte
RO
1
idx start object
long
RW
Contains the index and subindex of the object which
is displayed by the operator after the start.
2
supported baud rates
long
RO
List of supported baud rates
3
baud rate addr
word
RO
Address of the object to change the baud rate.
4
software version addr
long
RO
Address of the object of the software version.
5
software date addr
long
RO
Address of the object of the software date.
6
supported services 31-0
long
RO
List of supported DIN66019 services (31-0)
7
supported services 63-32
long
RO
List of supported DIN66019 services (63-32)
8
watchdog addr
long
RO
Address of the object of the watchdog function.
9
com mode
long
RW
Communication modes (see 0)
idx start object
0x200A [1]
Description
Default value:
Format: 0xSSSSIIII (highword = subindex, lowword = index)
0x00002C03
supported baud rates
0x200A [2]
Description
Default value:
Bit 0: Baud rate index 0 (1200 bit/s)
Bit 1: Baud rate index 1 (2400 bit/s)
Bit 2: Baud rate index 2 (4800 bit/s)
Bit 3: Baud rate index 3 (9600 bit/s)
Bit 4: Baud rate index 4 (19200 bit/s)
Bit 5: Baud rate index 5 (38400 bit/s)
Bit 6: Baud rate index 6 (55500 bit/s)
Bit 7: Baud rate index 7 (57600 bit/s)
Bit 8: Baud rate index 8 (100000 bit/s)
Bit 9: Baud rate index 9 (115200 bit/s)
Bit 10: Baud rate index 10 (125000 bit/s)
Bit 11: Baud rate index 11 (250000 bit/s)
Bit 12: Baud rate index 12 (500000 bit/s)
0x00000A20
(Bit 5, 9 and 11)
baud rate addr
0x200A [3]
Description
Default value:
Format: 0xIIII (index, subindex always 0, only VAR objects)
0x2B0E
software version addr
0x200A [4]
Description
Default value:
Format: 0xSSSSIIII (highword = subindex, lowword = index)
0x00002010
software date addr
0x200A [5]
Description
Default value:
Format: 0xSSSSIIII (highword = subindex, lowword = index)
0x00002011
supported services (31-0)
0x200A [6]
Description
Default value:
Bit 31 = service 31 …… Bit 0 = service 0
0x00244003
supported services (63-31)
0x200A [7]
Description
Default value:
Bit 63 = service 63 …… Bit 32 = service 32
0x00000000

Table of Contents

Other manuals for KEB COMBIVERT F6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F6 and is the answer not in the manual?

KEB COMBIVERT F6 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F6
CategoryController
LanguageEnglish

Related product manuals