3 Features C
*: Available for KX-TD1232 only. Features 3-43
Programming References
Section 4, System Programming,
[605]–[606] Outgoing Permitted CO Line Assignment — Day / Night
Feature References None
Operation References Not applicable.
CO Line Group
Description CO lines can be grouped into up to eight CO line groups. This
allows extensions to call outside parties without designating a
specific CO line, since a CO line is automatically selected from the
designated CO line group. All CO lines belonging to a CO line
group follow the assignment determined for that CO line group. A
list of assignments for each CO line group is shown below:
• The destination of Intercept Routing
• Disconnect Time
• Register Recall Signal Time
• Host PBX Access Code
• Pause Time (used in Speed Dialing and Recall)
Conditions • Each CO line can only belong to one CO line group.
• CO lines in a CO line group are selected uniformly if all lines belong to
the same system.
• If System Connection* is employed, a CO line group can include CO
lines in both systems. In this case, a CO line is first selected from the
user’s system. If all lines in the user’s system are in use, a line in the
other system is selected.
Programming References
Section 4, System Programming,
[401] CO Line Group Assignment
[409]–[410] Intercept Extension — Day / Night
[411] Host PBX Access Codes
[412] Pause Time
[413] Register Recall Signal Time
[414] Disconnect Time
Feature References None
Operation References Not applicable.