4.6 CO Line Programming
Disconnect Time
4-94 System Programming
414
Description Determines the amount of time between successive accesses to the
same CO line.
Selection • CO line group (TRG) number: 1 through 8,
( =all CO line groups)
• Time (seconds): 0.5 / 2.0 / 4.0
Default All CO line groups – 2.0 s
Programming 1. Enter 414.
Display: TRG Discnct Time
2. Press NEXT.
Display : TRK GRP NO?–>
3. Enter a CO line group number.
To program CO line group number 1, you can also press NEXT.
Display example: TRG1:2.0sec
4. Keep pressing SELECT until the desired time is displayed.
5. Press STORE.
6. To program another CO line group, press NEXT or PREV, or
SELECT and the desired CO line group number.
7. Repeat steps 4 through 6.
8. Press END.
Conditions • The disconnect time must be longer than the requirements of the central
office or the host PBX.
• To assign all CO line groups to one selection, press the key at step 3.
In this case, the display shows the contents programmed for CO line
group 1.
• Program [401] “CO Line Group Assignment” is used to assign each CO
line to a CO line group.
Feature References Section 3, Features,
Recall