4.8 Extension Programming
Outgoing Permitted CO Line Assignment — Day / Night
605-606
4-120 System Programming
Description Determines the CO lines which can be accessed by an extension in
both day and night modes. The extension users can make outgoing
outside calls using the assigned CO lines.
Selection • Jack number: KX-TD816 – 01 through 16, (-1 / -2),
KX-TD1232 – 01 through 64, (-1 / -2),
( =all jacks, -1 = first part, -2 = second part)
• CO line number:
KX-TD816 – 01 through 08, ( =all CO lines)
KX-TD1232 – 01 through 24, ( =all CO lines)
• Enabl (enable) / Disab (disable)
Default All jacks-1/2 – all CO lines – Enable — Day / Night
Programming 1. Enter a program address (605 for day or 606 for night).
Display example: CO Out Day
2. Press NEXT.
Display: Jack NO?->
3. Enter a jack number.
To enter jack number 01, you can also press NEXT.
To select the second part (-2), press NEXT after entering a jack number.
Display example: #01-1:CO01:Enabl
4. Enter the desired CO line number, or keep pressing or
until the desired CO line is displayed.
To change the current entry, enter the new number.
5. Keep pressing SELECT until the desired selection is
displayed.
6. Press STORE.
7. To program another jack, press NEXT or PREV, or SELECT
and the desired jack number.
8. Repeat steps 4 through 7.
9. Press END.