4.4 Timer Programming
Hold Recall Time
4-56 System Programming
200
Description Assigns the length of the hold recall timer. This timer is used to
alert an extension that a call has been held for an extended period
of time.
Selection Time (seconds): 0 through 240 (0=Hold Recall disabled)
Default 60 s
Programming 1. Enter 200.
Display: Hold Recall Time
2. Press NEXT.
Display example: Time: 60 sec
3. Enter the time.
To change the current entry, press CLEAR and the new time.
4. Press STORE.
5. Press END.
Conditions • Select “0” if Hold Recall is not required.
• You cannot leave the entry empty.
Feature References Section 3, Features,
Hold Recall