Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Description et caractéristiques d’un PBX 01/2011 Page 91
3.5.3 AXS/AXS12/AXS6 iPBX
An AXS/AXS12/AXS6 iPBX contains 3 slots numbered from 00 to 02, corresponding to
the following physical slots:
TABLEAU 3.10 SLOT NUMBERS ON THE BACKPLANE OF AN AXS/AXS12/AXS6
IPBX
The slots in a main cabinet can be fitted with all the Aastra X series cards.
The slots in an expansion cabinet can only be fitted with equipment cards.
Note : The three main cabinet slots are synchronising positions. H0 (in position 1-00) has priority
over H1 (in position 1-01), H2 (in position 1-02) and H3 (retrieved from the T0 interfaces built
into EXT1-S/EXT1-S12/EXT1-S6) which have the same priority level.
The following table summarises the possible slots, and gives restrictions concerning the
various expansion cards of the AXS/AXS12/AXS iPBX:
TABLEAU 3.11 POSSIBLE BASIC BACKPLANE AND EXTENSION EQUIPMENT
CONFIGURATION OF AN AXS/AXS12/AXS6 IPBX
02 01 00
UCV-S EXT1-S/EXT1-S12/
EXT1-S6
CARDS MAIN CABINET EXPANSION CABINET PARTICULAR CONSTRAINTS
CLX cards Yes Not Limited to 3
LD4/LD4N/LD4X Yes Not Limited to 3 (S0)
Limited to 2 (DECT)
LT2 Yes Not Limited to 2
IPS Yes Yes Limited to 1
PT2 Yes Not Limited to 1
CS1 Yes Not Limited to 3
CA1 Yes Not Limited to 3
CP1 Yes Not Limited to 3
MUM Yes Not Limited to 3
Equipment cards Yes Yes
LA8 Yes Yes
LA16X Yes Yes
LN16X Yes Yes
LA16X-8 Yes Yes
LN16X-8 Yes Yes
LN8 Yes Yes
LM8 Yes Yes
LH8 Yes Yes
LH16X Yes Yes
LH16X-8 Yes Yes
LR4 Yes Yes
LI1 Yes Yes
BTX Yes Yes Limited to 1