6-16 Chapter 6
D270/D370, D280/D380/R380 and D390/R390 Front Panel LCD Codes
Major Code Category 8: I/O Device Fault Codes
Table 6-9 I/O Device Fault Codes
Ostat Code Description
WARN 80F3 PDC IODC failed to retrieve header information
WARN 80F4 PDC IODC failed to return Entry Init
WARN 80F5 Error executing Entry Init
WARN 80F6 PDC IODC failed to return Entry I/O
WARN 80F7 Error executing Entry I/O
WARN 80F8 Invalid device class, must be sequential, random, or tftp
WARN 80F9 PDC IODC failed to return Entry Test
WARN 80FA Error executing Entry Test
WARN 80FC Invalid device (internal PDC structure error)
FLT 802B I/O bus overlap (usually due to graphics configuration violation)
FLT 803D To many graphics responding to the same address
WARN 8FFF Late I/O selftest warning
WARN 8xyA Hot swap retry due to spin-up time
TEST 8xy0 Begin HP-PB to GSC Bus adapter register tests
FLT 8xy1-8xy4 Failures of HP-PB to GSC Bus adapter register tests
Where x = GSC slot number and y = GSC bus number
TEST 8xy5 Begin HP-PB to GSC Bus adapter DMA tests
FLT 8xy6-8xyB Failures of HP-PB to GSC Bus adapter DMA tests
Note: These are NIO failures on the Access Port card.
TEST 8400 Begin MFIOC tests
INIT 8404 Initialize MFIOC
TEST 8404 Test the MFIOC RS232
FLT 8404 Failed MFIOC RS232 test
TEST 8405 Test the MFIOC SCSI
INIT 8405 Initialize MFIOC SCSI
FLT 8405 Failed MFIOC SCSI test
TEST 8406 Test the MFIOC LAN