0 = KTY 84-130, 1 = PTC, 2 = via encoder, 3 = KTY
83 110, 4 = PT1000
Standstill current (permanent permissible current at
standstill) in % of rated motor current
Rated current = permanent permissible current at
rated speed
Application point of the motor protection function in
% of the permanent permissible current
Max. current in % rated motor current
Time, after the protection function is triggered at
min. current flow (defined dr38)
Time, after the protection function is triggered at
max. current flow (defined dr12)
The prot. recovery time is the time, which the pro-
tection function counter needs to count from 100%
to 0%.
The overtemperature motor protection is parameterized with this objects (=> Chap-
ter 4.4.5 Overtemperature motor (dOH) and chapter 4.4.6 Motor protection switch
OH2 ).