ENGINE
B2650HSDC, B3350HSDC, WSM
1-M18
(6) Warning Level (Default Version)
PM warning level 0 to 5 as shown below is programmed according to the amount of accumulated PM to prompt
the operator to perform the required procedure in each level.
• Level 0: Normal operation. Regeneration is not required.
• Level 1: Auto Regeneration is possible in the Auto Regeneration Mode.
• Level 2: Auto Regeneration is possible in the Auto Regeneration Mode. Parked Regeneration is possible in both
of the Auto Regeneration Mode and Inhibit Mode.
• Level 3: Auto Regeneration is not possible in above level 3. Parked Regeneration is required as soon as possible.
• Level 4: Only by using diagmaster, Parked Regeneration is possible. Parked Regeneration is required as soon
as possible.
• Level 5: Replacement is required. Regeneration is not possible.
9Y1210822ENM0037US0
Auto Regeneration Mode
: OFF, : Blink, : ON
9Y1210822ENM0038US0
Warning
level
Buzzer
Engine
output
limitation
Remark
0No
No
limitation
Normal operation, Regeneration is not required.
1No
No
limitation
Under the Auto Regeneration or preparation for Auto
Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Keep on working and increase the engine rpm until
regeneration indicator stops flashing and remains constant
"ON".
2-1
Every 5
seconds
No
limitation
Under the Auto Regeneration or preparation for Auto
Regeneration.
2-2
Every 3
seconds
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Keep on working and increase the engine rpm until
regeneration indicator stops flashing and remains constant
"ON".
3
Every
second
50 %
Condition for Parked Regeneration is not satisfied.
Condition for Parked Regeneration is satisfied. When
pressing the parked regeneration switch, Parked
Regeneration will start.
Under the preparation for Parked Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Under the Parked Regeneration.
4
Every
second
50 %
Without diagmaster.
Condition for Parked Regeneration is not satisfied.
Condition for Parked Regeneration is satisfied. When
pressing the parked regeneration switch, Parked
Regeneration will start.
Under the preparation for Parked Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Under the Parked Regeneration.
5
Every
second
50 %
Even when using diagmaster, it is not possible to do Parked
Regeneration.