Reference Point Approach (R1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
5-1
Data Lists
5
5.1 5.1 Machine data
5.1.1 NC-specific machine data
Number Identifier: $MN_ Description
11300 JOG_INC_MODE_LEVELTRIGGRD INC/REF in jog/continuous mode
5.1.2 Channel-specific machine data
Number Identifier: $MC_ Description
20700 REFP_NC_START_LOCK NC start disable without reference point
5.1.3 Axis/spindle-specific machine data
Number Identifier: $MA_ Description
30200 NUM_ENCS Number of encoders
30240 ENC_TYP Actual value encoder type
30242 ENC_IS_INDEPENDENT Encoder is independent
30250 ACT_POS_ABS Absolute encoder position at time of deactivation.
30270 ENC_ABS_BUFFERING Absolute encoder: Traversing range extension
30300 IS_ROT_AX Rotary axis/spindle
30310 ROT_IS_MODULO Modulo conversion for rotary axis/spindle
30330 MODULO_RANGE Magnitude of the modulo range
30340 MODULO_RANGE_START Starting position of modulo range
30355 MISC_FUNCTION_MASK Axis functions
31122 BERO_DELAY_TIME_PLUS BERO delay time in plus direction