EasyManuals Logo
Home>Siemens>Control Systems>SINUMERIK ONE MCP 2400.4c

Siemens SINUMERIK ONE MCP 2400.4c Function Manual

Siemens SINUMERIK ONE MCP 2400.4c
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #788 background imageLoading...
Page #788 background image
Detailed Description
2.4 Frames
Axis Types, Coordinate Systems, Frames (K2)
2-58 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2.4.6 Frame chain frames
2.4.6.1 Overview
There are up to four frame variants:
Settable frames (G500,G54 to G599)
Basic frames
Programmable frame
System frames
2.4.6.2 Settable frames $P_UIFR[n]
The number of NCU global settable frames is set via machine data
MD18601 $MN_MM_NUM_GLOBAL_USER_FRAMES.
The number can be between 0 and 100.
If the machine data has a value greater than zero, there are only NCU global settable
frames, otherwise the machine data
MD28080 $MC_MM_NUM_USER_FRAMES
specifies the number of channel-specific settable frames.
System variable $P_UIFR[n] can be used to read and write the frame field elements. The
frame is not activated simultaneously when writing a field element, but rather activation only
takes place on execution of a G500,G54, to G599 instruction. For NCU global frames, the
changed frame only becomes active in those channels of the NCU, which execute a
G500,G54 to G599 instruction. The variable is used primarily for storing write operations
from HMI or PLC. These frame variables are saved by the data backup.
Current settable frame $P_IFRAME
The predefined frame variable $P_IFRAME can be used to read and write the current
settable frame, which is valid in the channel, in the part program. The written settable frame
is immediately included in the calculation. In the case of NCU global settable frames, the
modified frame acts only in the channel in which the frame was programmed. If the frame is
to be modified for all channels of an NCU, $P_UIFR[n] and $P_IFRAME must be written
simultaneously. The other channels must then activate the corresponding frame, e.g., with
G54.
Programming of settable frames
Settable frames can be read and written via the part program and via the OPI by operator
actions and by the PLC. However, only data management frames can be written by the OPI.
The index of the active settable frame can be ascertained via the $P_UIFRNUM system
variable.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals