Auxiliary Function Output to PLC (H2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-1
Detailed Description
2
2.1 2.1 Predefined auxiliary functions
2.1.1 Predefined auxiliary functions
Function
Predefined auxiliary functions are auxiliary functions for activating system functions. The
assignment of a predefined auxiliary function to system function cannot be changed.
During execution of a predefined auxiliary function, the corresponding system function is
activated and the auxiliary functions are output to the NC/PLC interface.
Definition of a predefined auxiliary function
The parameters of a predefined auxiliary function are stored in machine data and can be
changed in some cases. All parameters of an auxiliary function have the same index.
MD22040 $MC_AUXFU_PREDEF_GROUP[ index ] (group assignment)
MD22050 $MC_AUXFU_PREDEF_TYPE[ index ] (type)
MD22060 $MC_AUXFU_PREDEF_EXTENSION[ index ] (address extension)
MD22070 $MC_AUXFU_PREDEF_VALUE[ index ] (value)
MD22080 $MC_AUXFU_PREDEF_SPEC[ index ] (specification of output behavior)

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals