Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
5-1
Data Lists
5
5.1 5.1 Machine data
5.1.1 Memory specific machine data
Number Identifier: $MM_ Description
9004 DISPLAY_RESOLUTION Display resolution
9010 SPIND_DISPLAY_RESOLUTION Display resolution for spindles
9011 DISPLAY_RESOLUTION_INCH Display resolution for INCH system of measurement
5.1.2 NC-specific machine data
Number Identifier: $MN_ Description
10000 AXCONF_MACHAX_NAME_TAB[n] Machine axis name
10050 SYSCLOCK_CYCLE_TIME System basic cycle
10070 IPO_SYSCLOCK_TIME_RATIO Factor for interpolator cycle
10060 POSCTRL_SYSCLOCK_TIME_RATIO Factor for position-control cycle
10080 SYSCLOCK_SAMPL_TIME_RATIO Division factor of position-control cycle for actual-
value acquisition
10200 INT_INCR_PER_MM Computational resolution for linear positions
10210 INT_INCR_PER_DEG Computational resolution for angular positions
10220 SCALING_USER_DEF_MASK Activation of scaling factors
10230 SCALING_FACTORS_USER_DEF[n] Scaling factors of physical quantities
10240 SCALING_SYSTEM_IS_METRIC Basic system metric
10250 SCALING_VALUE_INCH Conversion factor for switchover to
inch system
10260 CONVERT_SCALING_SYSTEM Basic system switchover active
10270 POS_TAB_SCALING_SYSTEM Measuring system of position tables
10290 CC_TDA_PARAM_UNIT Physical units of the tool data for CC
10292 CC_TOA_PARAM_UNIT Physical units of the tool edge data for CC
13000 DRIVE_IS_ACTIVE[n] Drive activation