Detailed Description
2.3 Type-specific output behavior
Auxiliary Function Output to PLC (H2)
2-18 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Machine data Machine data index Value
MD22000 $MC_AUXFU_ASSIGN_GROUP 2 5
MD22010 $MC_AUXFU_ASSIGN_TYPE 2 'M'
MD22020 $MC_AUXFU_ASSIGN_EXTENSION 2 2
MD22030 $MC_AUXFU_ASSIGN_VALUE 2 5
MD22035 $MC_AUXFU_ASSIGN_SPEC 2 H91
2.3 2.3 Type-specific output behavior
Function
The output behavior of the auxiliary function relative to a traverse motion programmed in the
part program block can be defined type-specifically in the following machine data:
MD22200 $MC_AUXFU_M_SYNC_TYPE (output time M functions)
MD22210 $MC_AUXFU_S_SYNC_TYPE (output time S functions)
MD22220 $MC_AUXFU_T_SYNC_TYPE (output time T functions)
MD22230 $MC_AUXFU_H_SYNC_TYPE (output time H functions)
MD22240 $MC_AUXFU_F_SYNC_TYPE (output time F functions)
MD22250 $MC_AUXFU_D_SYNC_TYPE (output time D functions)
MD22252 $MC_AUXFU_DL_SYNC_TYPE (output time DL functions)

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals