Detailed Description
2.5 Optimization of the control
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-61
Supplementary condition
1. The functional expansion is available for all control variants,
which use SIMODRIVE 611 digital drives.
2. The function can only be used on axes with two encoders:
MD30200 $MA_NUM_ENCS = 2
One of the encoders must be parameterized as an indirect measuring system and the
other as a direct measuring system.
If these conditions are not met, reset alarm 26016 will acknowledge the function when an
attempt is made to activate machine data:
MD32950 $MA_POSCTRL_DAMPING.
The function remains deactivated internally when this alarm is active.
2.5.2 Position controller position setpoint filter: new balancing filter
For speed and torque feedforward control
Application
With feedforward control active, the position setpoint is sent through a socalled balancing
filter before it reaches the controller itself. It is thus possible to feedforward control the speed
setpoint at 100%, without resulting in overshoots when positioning.
Functionality
Until now, it was possible to compensate the negative effects of the balancing filter (a low
pass with settable time constant), which has remained unchanged since SW 1 and which
has admitted instead of an overshoot also undesired undershoots of some 10 micrometers,
as follows:
Setting a compromise of overshoots and undershoots
Setting the positioning slightly overshooting and reducing the amplitude of these
overshoots by way of position setpoint signal smoothing and jerk limitation
Setting a speed controller with reference model instead of PI behavior
(only possible with 840D)
Setting the filter time to zero and setting the feedforward control factor to a value less
than 100%
Sacrificing the feedforward control and bringing the machine to a very high position
controller gain using dynamic stiffness control.
This measure requires a stiff machine.
With SW 5 and higher, a second, improved balancing filter is therefore available.
The existing filter is still installed and is active with the same function when transferring
existing archives (e.g. in the case of upgrades).

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals