Detailed Description
2.10 Working with tool environments
Tool Compensation (W1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-139
2.10.2 Saving with TOOLENV
Scope of a tool environment
The TOOLENV memory function is used to save any current states needed for the evaluation
of tool data stored in the memory.
The individual data are as follows:
The active G code of group 6 (G17, G18, G19)
The active G code of group 56
(TOWSTD, TOWMCS, TOWWCS, TOWBCS, TOWTCS, TOWKCS)
The active transverse axis
Machine data MD20360 $MC_TOOL_PARAMETER_DEF_MASK
Machine data MD18112 $MN_MM_KIND_OF_SUMCORR
Setting data SD42935 $SC_WEAR_TRANSFORM
Setting data SD42950 $SC_TOOL_LENGTH_TYPE
Setting data SD42940 $SC_LENGTH_CONST
Setting data SD42900 $SC_MIRROR_TOOL_LENGTH
Setting data SD42910 $SC_MIRROR_TOOL_WEAR
Setting data SD42930 $SC_WEAR_SIGN
Setting data SD42920 $SC_WEAR_SIGN_CUTPOS
The orientation component of the current complete frame (rotation and mirroring, no work
offsets or scales)
The orientation component and the resulting length of the active toolholder with
orientation capability
The orientation component and the resulting length of an active transformation
In addition to the data describing the environment of the tool, the T number, D number
and DL number of the active tool are also stored, so that the tool can be accessed later in
the same environment as the TOOLENV call, without having to name the tool again.
Not in the tool environment
The value of machine data:
MD18105 $MN_MM_NUM_TOOL_ADAPTER
determines whether the adapter length or the tool base dimension is included in the tool
length calculation.
Since a change to this machine data only takes effect after Power On, it is not saved in the
tool environment.

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals