2.1 Various interface signals and functions (A2)
NC/PLC Interface Signals (Z1)
2-22 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
DB19
DBX25.0 - DBX25.7
Error RS-232-C
Corresponding to .... Applies to HMI Embedded
DB19
DBX26.1
OK (job list selection from PLC, status)
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
Transfer correctly completed
Signal state 0 or
edge change 1 → 0
Transfer completed with error
Corresponding to .... Valid for HMI Advanced
DB19
DBX26.2
Error (job list selection from PLC, status) (previously bit 0)
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
Transfer completed with error
Signal state 0 or
edge change 1 → 0
Transfer correctly completed
Corresponding to .... Valid for HMI Advanced
DB19
DBX26.3
Active (job list selection from PLC, status)
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
Job in progress
Signal state 0 or
edge change 1 → 0
No task in progress
Corresponding to .... Valid for HMI Advanced