5.3 Code Index by Purpose
5-50
[2] PID process control
Table 5.3-19
To
Function
code
Name
Refer to
page:
Exercise process control for pressure, flow, temperature, etc. J01 PID Control (Mode selection) 5-214
Normal/inverse
operation
Switch between normal/reverse operation for
the PID output in cooling and heating.
J01
E01 to E09
PID Control (Mode selection)
Terminal [X1] to [X9] Functions
(IVS)
5-214
5-122
Specify a PID command using the keypad. J02 PID Control (Remote command) 5-215
J02
E61
E62
E63
PID Control (Remote command)
Terminal [12] Extended Function
Terminal [C1] Extended Function
Terminal [V2] Extended Function
5-215
5-162
C51
C52
Bias (PID command 1)
(Bias value)
(Bias base point)
5-174
C32
C34
C37
C39
C42
C44
Analog Input Adjustment for:
[12] (Gain)
[12] (Gain base point)
[C1] (Gain)
[C1] (Gain base point)
[V2] (Gain)
[V2] (Gain base point)
5-173
C31
C36
C41
Analog Input Adjustment for:
[12] (Offset)
[C1] (Offset)
[V2] (Offset)
5-173
C33
C38
C43
Analog Input Adjustment for:
[12] (Filter)
[C1] (Filter)
[V2] (Filter)
5-173
Specify a PID command with analog input.
C35
C45
Analog Input Adjustment for:
[12] (Polarity)
[V2] (Polarity)
5-173
Specify a PID command with UP or DOWN
command.
J02
E01 to E09
H61
PID Control (Remote command)
Terminal [X1] to [X9] Functions
(UP, DOWN)
UP/DOWN Control (Initial
frequency setting)
5-215
5-122
5-62
Specify a PID command via a communications
link.
J02 PID Control (Remote command) 5-215
PID command
Define different PID commands beforehand and
switch them with the multi-frequency selection
signals.
J02
E01 to E09
C08
C12
C16
PID Control (Remote command)
Terminal [X1] to [X9] Functions
(SS4, SS8)
Multi-frequency 4
Multi-frequency 8
Multi-frequency 12
5-215
5-122
5-166
E61
E62
E63
Terminal [12] Extended Function
Terminal [C1] Extended Function
Terminal [V2] Extended Function
5-162
PID feedback Set up analog input feedback for PID control.
C32
C34
C37
C39
C42
C44
Analog Input Adjustment for:
[12] (Gain)
[12] (Gain base point)
[C1] (Gain)
[C1] (Gain base point)
[V2] (Gain)
[V2] (Gain base point)
5-173

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric Frenic Mega Series and is the answer not in the manual?

Fuji Electric Frenic Mega Series Specifications

General IconGeneral
BrandFuji Electric
ModelFrenic Mega Series
CategoryInverter
LanguageEnglish

Related product manuals