5.3 Code Index by Purpose
5-60
[2] Maintenance of machinery
Table 5.3-28
To:
Function
code
Name
Refer to
page:
Check the cumulative motor run time. H94 Cumulative Motor Run Time 1 5-201
Cumulative
motor run time
Count the cumulative motor run time even when
the motor is driven by commercial power.
E01 to E09
Terminal [X1] to [X9] Functions
(CRUN-M1, M2, M3, M4)
5-122
Startup count for
motor
Check the startup count for judging the service
life of the drive belt used in the machinery if the
belt deteriorates due to the starting torque
applied every time of startups.
H44 Startup Counter for Motor 1 5-196
Signal the need of the maintenance, based on
the cumulative motor run time.
H78
E20 to E24
Maintenance Interval (M1)
Terminal [Y1] to [Y5A/C]
Functions (MNT)
5-201
5-141
Maintenance
timer
Signal the need of the maintenance, based on
the inverter startup count.
H79
E20 to E24
Preset Startup Count for
Maintenance (M1)
Terminal [Y1] to [Y5A/C]
Functions (MNT)
5-202
5-141
Switching
between remote
and local modes
Separate the inverter from the system and drive
it with commands entered from the keypad, for
maintenance.
E01 to E09
E20 to E24
Terminal [X1] to [X9] Functions
(LOC)
Terminal [Y1] to [Y5A/C]
Functions (RMT)
5-122
5-141