Error Messages, Codes, and Procedures 3-27
Fuser Failure - U4-1 On Time
Note
Following display of this error, leave power applied for 7 minutes, then cycle
printer power. If the error reoccurs, procede with troubleshooting procedure.
The Fuser failed to reach temperature within the warm-up period. Possible faults are:
â– During the Warm-Up period, the Control Thermistor does not detect the
Ready temperature even when the specified time has passed.
â– During the Standby period, the Control Thermistor does not detect the
required temperature even when the specified time has passed.
â– During the Standby period, the Control Thermistor does not detect the
required temperature even when the specified time has passed.
â– During idling after power-on, the Control Thermistor does not detect the
idling stop temperature even after the specified time has passed.
â– During print, the Control Thermistor does not detect the required
temperature even when the specified time has passed.
4
Check the Laser connections.
Are P/J130, P/J620 and P/J406
connected?
Go to Step 5. Connect P/J130,
P/J620 and P/
J406.
5
Check continuity between the Laser and
the Engine Logic Board.
Is there continuity on each wire
between P/J140 <=> P/J406?
Go to Step 6. Repair the wiring.
6
Check continuity between the Laser and
the Engine Logic Board.
Is there continuity on each wire
between P/J130 <=> P/J406?
Go to Step 7. Repair the wiring.
7
Check for +5 V to the Laser.
Is there +5 V across P/J140-8 (+) <=>
ground?
Go to Step 8. Replace the
Engine Logic
Board
(
page 8-89).
8
Check for +24 V to the Laser.
Is there +24 V across P/J130-5 (+) <=>
ground?
Replace the Laser
assembly
(
page 8-74).
Replace the
Engine Logic
Board
(
page 8-89).
Scanner Motor Troubleshooting Procedure (Continued)
Step Actions and Questions Yes No