Error Messages, Codes, and Procedures 3-179
Eject Clamp (Set Clamp Home Sensor) Troubleshooting Reference
Applicable Parts References
â– Set Clamp Home
Sensor
â– Main Sensor Harness
â– Finisher Main PWB
â– Eject Bracket
Assembly
â– Main Drive Harness
â– Set Clamp Clutch
â– Phaser 5500 Printer Options Service Manual
â– Finisher Main PWB P/J Locator (page 5-35)
â– Finisher Compiler P/J Locator (page 5-33)
â– Finisher Sensors (2/2) Wiring (page 5-41)
â– Finisher Clutch and Solenoids Wiring (page 5-43)
â– PL25.10 Finisher Eject (2/3) (page 4-62)
â– PL25.14 Finisher Electrical (page 4-70)
â– PL25.15 Finisher Harness (page 4-72)
Eject Clamp (Set Clamp Home Sensor) Troubleshooting Procedure
Step Actions and Questions Yes No
1
Check the Eject Clamp operation.
Rotate the Eject Clamp Motor.
Does the Eject Clamp move smoothly?
Go to Step 2. Correct the
installation.
2
Test the Set Clamp Home Sensor.
Run the Service Diagnostics Set Clamp
Home Sensor test.
Does the sensor change state?
Go to Step 8. Go to Step 3.
3
Check the Set Clamp Home Sensor
Harness connection.
Are P/J8325 and P/J8302B connected?
Go to Step 5. Connect and go
to Step 4.
4
Print a Test Print.
Does the error still occur?
Go to Step 5. Problem solved.
5
Check the Set Clamp Home Sensor
Harness continuity.
1. Disconnect P/J8325 and P/J8302B.
2. Check for continuity at the following:
P/J8325-3 <=> P/J8302B-4
P/J8325-2 <=> P/J8302B-9
P/J8325-1 <=> P/J8302B-11
Are these conductive?
Go to Step 6. Repair the Set
Clamp Home
Sensor Harness.
6
Check for +5 V to the Set Clamp Home
Sensor.
Is there +5 V across J8302B-11 <=>
J8302B-9 on the Finisher Main PWB for
H5-83?
Is there +5 V across J8302B-4 <=>
J8302B-9 on the Finisher Main PWB for
H5-84?
Go to Step 7. Replace the
Finisher Main
PWB
(