7-23
dummyheaddummyhead
FUEL SYSTEM
INSTALLATION
Turn the slide valve [1] clockwise until lightly seated on
IACV.
Install a new O-ring [1] to the IACV [2].
Install the IACV by aligning its groove with the slide
valve housing pin.
Install the setting plate [3] while aligning its cut-out with
the tab on the IACV.
Install and tighten the IACV setting plate torx screws [4]
securely.
Connect the IACV 4P (Black) connector [5].
Install the air cleaner housing (page 7-14).
[5]
[2]
[3]
Align
[4]
[1]
Align