2H0/2HZ
1-3-75
U905
Checking/clearing counts by optional devices
Description
Displays or clears the counts of optional DP or finisher.
Purpose
To check the use of optional DP and finisher. Also to clear the counts after replacing consumable parts.
Method
1. Press the start key.
2. Select the device, the count of which is to be checked. The count of the selected device is displayed.
DP
Finisher
Clearing
1. Select the item to be cleared.
To clear the counts for all, press the clear key.
2. Press the start key. The count is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U906
Resetting partial operation control
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the casettes or other sections, and the
related parts are serviced.
Method
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key to reset partial operation control.
The maintenance mode is exited, and the machine returns to the same status as when the main power
switch is turned on.
Maintenance
item No.
Description
Display Description
DP Counts of optional DP
FINISHER Counts of optional finisher
Display Description
ADP No. of single-sided originals that has passed through the DP
RADP No. of double-sided originals that has passed through the DP
Display Description
CP CNT No. of copies that has passed
STAPLE Frequency the stapler has been activated