2H0/2HZ
1-4-38
(18) Image center does not align with the original center.
Copy example Causes Check procedures/corrective measures
Misadjusted image center line. Run maintenance item U034 to readjust the center line of
image printing (see page 1-3-21).
Misadjusted scanner center line. Run maintenance item U067 to readjust the scanner leading
edge registration (see page 1-3-29).
Original is not placed correctly. Place the original correctly.