M800S/M80/E80 Series Connection and Setup Manual
4 General Specifications
164
IB-1501269-J
[LED]
(Note 1) Ignore LED which is not written in the table above.
No. Name Green LED Red LED Details
(1) MS (Green/Red)
(Module status)
Flashing Flashing In self-test
Flashing Not lit Waiting for initialization
Lit Not lit Normal operation
Not lit Flashing Recoverable failure
Not lit Lit
Unrecoverable failure (The hardware needs to be
replaced.)
(2) NS (Green/Red)
(Communication status)
Flashing green/red
(alternately)
In self-diagnosis
Not lit Not lit No IP address
Flashing Not lit No connection
Lit Not lit Normal operation
Not lit Flashing Connection time out
Not lit Lit IP address duplication
(1)
(2)
(1) (2)