M800S/M80/E80 Series Connection and Setup Manual
7 Connection of Control Unit
256
IB-1501269-J
7.12.3 Connecting I/O Device via CC-Link IE Field
The expansion unit FCU8-EX564 functions as a master station or slave (local) station of CC-Link IE Field. Connect the
CC-Link IE Field-compatible equipment with an ethernet cable (category 5e or above and twisted pair shield cable).
For details, refer to "M800/M80 Series CC-Link IE Field (Master/local) Specifications manual".
[Noise countermeasures of ethernet cable]
When the CC-Link IE Field unit is being used, expose the cable by removing a part of the cable sheath and make
sure to use the shield clamp for the exogenous noise countermeasure.
When you cannot use the shield clamp, make sure to install a ferrite core as a substitute to ethernet cable (near the
expansion unit).
<Related item>
Shield clamp fitting: "EMC Installation Guidelines: EMC Countermeasure Parts: Shield Clamp Fitting"
Ferrite core: "EMC Installation Guidelines: EMC Countermeasure Parts: Ferrite Core"
(FCU8-EX70x)
(FCU8-EX564)
Connector for
CC-Link IE Field
communication
Option relay unit
CC-Link IE Field unit
(* Prepared by MTB)
Switching hub
Slave station
Ethernet cable
(category 5e or above and
twisted pair cable with shield)
CC-Link IE Field-compatible equipment
Slave station
Slave station
Shield
Ethernet cable

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi M80 series and is the answer not in the manual?

Mitsubishi M80 series Specifications

General IconGeneral
BrandMitsubishi
ModelM80 series
CategoryControl Unit
LanguageEnglish

Related product manuals