M800S/M80/E80 Series Connection and Setup Manual
15 Cable
358
IB-1501269-J
15.2.19 J225 Cable
Max. cable length: 30m
Application: Analog output cable (for operation panel I/O unit)
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
(Note 2) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly
otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05Nꞏm)
15.2.20 J303 Cable
Max. cable length: 50m
Application: LAN straight cable
[AO]
Connector : 10120-3000PE
Case : 10320-52F0-008
Recommended manufacturer : 3M
Wire material :
UL2464 U-TKVVBS AWG24 × 1P
Recommended manufacturer :
Tachii Electric Wire
Crimp terminal : R1.25-3.5 x 2P
Recommended manufacturer : JST
[LAN]
Connector : J00026A0165
Boot : B00080F0090
Recommended manufacturer :
JAPAN Telegärtner
Wire material :
FANC-IEF-SB 24AWG × 4P
Recommended manufacturer :
Kuramo Electric
AO
AI0
AO
AOG
AO
7
1
AOG
AO
AOG
AO
LAN LAN
LAN LAN
1
2
3
6
4
5
7
8
1
2
3
6
4
5
7
8
Double shield
ShieldShield
Shell Shell
White
orange
Orange
White
green
Green
Blue
White
blue
White
brown
Brown
White
orange
Orange
White
green
Green
Blue
White
blue
White
brown
Brown

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi M80 series and is the answer not in the manual?

Mitsubishi M80 series Specifications

General IconGeneral
BrandMitsubishi
ModelM80 series
CategoryControl Unit
LanguageEnglish

Related product manuals