M800S/M80/E80 Series Connection and Setup Manual
9 Connection of Operation Panel I/O Unit
282
IB-1501269-J
9.9 Connecting with Analog Output Signal (FCU8-DX731)
For the analog output signals, connect J225 cable to the AO connector of FCU8-DX731.
The analog output signals are available to connect up to one point for the input, and up to one point for the output.
<Related items>
Cable drawing "Cable: J225 Cable"
Connector pin assignment: "General Specifications: Operation Panel I/O Unit" (AO connector)
AO
J225
ã»­ã»»
AO
15
7
AO
0V
1
11
5
FCU8-DX731
FG
Shell
Machine side
Shield