M800S/M80/E80 Series Connection and Setup Manual
7 Connection of Control Unit
233
IB-1501269-J
7.4 Connecting with Operation Panel I/O Unit
Connect the operation panel I/O unit to CJ71 connector of the control unit.
[FCU8-DX731 / FCU8-DX750 / FCU8-DX760 / FCU8-DX761]
[FCU8-DX834]
<Related items>
Cable drawing "Cable : J010 Cable" and "Cable : J012 Cable"
Connector pin assignment: "General Specifications: Control Unit" (CJ71 connector)
CJ71
CJ71
J010
RIO3EXT
RIO2.0
A
B
AMP D-2
(R2-TM)
Control unit Operation panel
I/O unit
Terminator
connector
CJ71
RIO3
J012
RIO3EXT
RIO2.0
A
B
AMP D-2
(R2-TM)
Control unit Operation panel
I/O unit
Terminator
connector