M800S/M80/E80 Series Connection and Setup Manual
4 General Specifications
185
IB-1501269-J
4.18 Handy Terminal
(Note 1) "Short term" means within one month.
(Note 2) The unit is an IP65F equivalent.
Item
Unit name Handy terminal
Type HG1T-SB12UH-MK1346-L5
General
Specifications
Ambient
temperature
During
operation
0 to 40 ℃
During
storage
-20 to 60 ℃
Ambient
humidity
Long term: 10 to 75% RH (with no dew condensation)
Short term: 10 to 95% RH (with no dew condensation) (Note 1)
Vibration
resistance
During
operation
9.8m/s
2
[1.0G] or less, 10 to 55Hz
Shock
resistance
During
storage
98m/s
2
[10.0G] or less
Working
atmosphere
No corrosive gases, dust or oil mist
Power
specifications
Power voltage 24VDC±5% Ripple noise 240mV (P-P)
Current
consumption
(max.) 0.2A
Instantaneous
stop tolerance
time
24VDC: 4ms or less
Others
Heating value 4W (max.)
Mass 0.6kg

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi M80 series and is the answer not in the manual?

Mitsubishi M80 series Specifications

General IconGeneral
BrandMitsubishi
ModelM80 series
CategoryControl Unit
LanguageEnglish

Related product manuals