Page #382 background image
M800S/M80/E80 Series Connection and Setup Manual
15 Cable
345
IB-1501269-J
15.2.4 G430 Cable
Max. cable length: 10m
Application: For connection to handy terminal
(Note) Fold the cable shield over the sheath, and wrap copper foil tape over it.
Connect the wound copper foil tape to GND plate of the connector.
[ENC][SIO]
Plug: 10120-3000VL
Shell: 10320-52F0-008
Recommended manufacturer: 3M
Wire material: UL1061-2464 AWG28 x
3P
Recommended manufacturer: Oki
Electric Cable
[Control panel terminal block]
Crimp terminal: R1.25-3.5
Recommended manufacturer: JST
Wire material: UL1061-2464 AWG24 x
8P
Recommended manufacturer: Oki
Electric Cable
FG terminal
Crimp terminal: V1.25-4
Recommended manufacturer: JST
Wire material: UL1061-2464
AWG18(Green)
Recommended manufacturer: Oki
Electric Cable
[HOST]
Plug: CDB-25S
Contact: CD-SC-221 ×21
Recommended manufacturer: Hirose
Electric
ENC
HOST
SIO
Control unit
Cotrol panel
terminal block
Handy terminal
HOST
16
17
20
14
15
7
8
6
8
18
5
HA1A
HA1B
0V
RD(RXD)
SD(TXD)
CS(CTS)
RS(RTS)
DR(DSR)
ER(DTR)
HA
HB
0V
SD(TXD)
RD(RXD)
RS(RTS)
CS(CTS)
0V
FG
FG
7
17
8
18
9
19
11
9
10
DED1
DCOM1
SW2_C11
SW2_C12
21
22
DED2
DCOM2
SW2_C21
SW2_C22
11
12
EMG1
ECOM1
SW1_NC11
SW1_NC12
23
24
EMG2
ECOM2
SW1_NC21
SW1_NC22
18
19
SEL1
SCOM1
SW6_NO1
SW6_C1
25
13
+24V
0V
0V
FG
ENC
SIO
1
FG
24VDC(+)
24VDC(-)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi M80 series and is the answer not in the manual?

Mitsubishi M80 series Specifications

General IconGeneral
BrandMitsubishi
ModelM80 series
CategoryControl Unit
LanguageEnglish

Related product manuals