M800S/M80/E80 Series Connection and Setup Manual
22 Setting the Position Detection System
466
IB-1501269-J
22.1.4 Machine End Stopper Method: Manual Initialization
(1) Preparations
Set the parameters on the
[Abs.Posit.Param.] screen.
#2049 type (absolute position detection type) = 1 (stopper method)
#2054 clpush (current limit) = 0 to 100
#2059 zerbas (select zero point parameter and basic point) =0
(position where the axis was stopped) *1
The parameters other than "#2049 type" can also be set on [Absolute
position setting screen].
(2) Turn the power OFF and ON.
(Only when "#2049 type" has been reset.)
The following are the operations on [Absolute position setting screen].(Select [Mainte] - [To Abs pos])
(3) Select the axis set to type 1 on the
[Abs.Posit.Param.] screen.
Select the menu [Axis select], enter
the axis name (#1022 axname2
(display axis name)) in the input area
and then press [INPUT].
(4) Select "HANDLE" or "JOG" for the
mode selection of machine operation
switch.
(5) Confirm that the cursor is placed on
"Absolute posn set", input "1" in the
input area and press the [INPUT] key.
The input value is registered in the "Absolute posn set" area.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi M80 series and is the answer not in the manual?

Mitsubishi M80 series Specifications

General IconGeneral
BrandMitsubishi
ModelM80 series
CategoryControl Unit
LanguageEnglish

Related product manuals