M800S/M80/E80 Series Connection and Setup Manual
21 Confirming the Basic Operation
451
IB-1501269-J
21.2 Confirming Manual Operation
21.2.1 Using the Manual Pulse Generator
(1) Select the handle mode.
(2) Set the handle feed magnification to a minimum value.
(3) Cancel the emergency stop. Confirm the operation status displays "RDY". (Note 2)
(Note 1) If any abnormal noise or vibration occurs, execute an emergency stop and take a measure against
vibration. (Refer to "First Measure Against Vibration".)
(Note 2) If there is a keyboard, it can also be confirmed with the READY lamp ON.
(4) Select an axis and turn the manual pulse generator by one scale. Confirm the direction and the amount of the
movement on the current position display.
If the display is not correct, check parameters, PLC programs and devices' connections.
(5) Turn the manual pulse generator and confirm the direction and the amount of the machine's movement.
If the display is not correct, check parameters.
(Related parameters: "#1018 ccw (Motor CCW)", "#2201 SV001(PC1) (Motor side gear ratio)", "#2202 SV002(PC2)
(Machine side gear ratio)", "#2218 SV018(PIT) (Ball screw pitch)" and so on)
(Note) Take care of the machine's movement range during the operation.
(6) Check the rest of the axes for each with the same operation as above.
21.2.2 Using JOG Feed
(1) Select JOG mode.
(2) Set the manual feed rate to 100mm/min.
(3) Cancel the emergency stop. Confirm the operation status displays "RDY". (Note 2)
(Note 1) If any abnormal noise or vibration occurs, execute an emergency stop and take a measure against
vibration. (Refer to "First Measure Against Vibration". )
(Note 2) If there is a keyboard, it can also be confirmed with the READY lamp ON.
(4) Select an axis, press the JOG feed button and move the axis to safe area. Confirm the direction and the amount of
the movement on the current position display.
If the display is not correct, check parameters, PLC programs and devices' connections.
(5) Confirm the direction and the amount of machine's movement.
If the display is not correct, check parameters.
(Related parameters: "#1018 ccw (Motor CCW)", "#2201 SV001(PC1) (Motor side gear ratio)", "#2202 SV002(PC2)
(Machine side gear ratio)", "#2218 SV018(PIT) (Ball screw pitch)" and so on)
(Note) Take care of the machine's movement range during the operation.
(6) Check the rest of the axes for each with the same operation as above.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi M80 series and is the answer not in the manual?

Mitsubishi M80 series Specifications

General IconGeneral
BrandMitsubishi
ModelM80 series
CategoryControl Unit
LanguageEnglish

Related product manuals