M800S/M80/E80 Series Connection and Setup Manual
4 General Specifications
34
IB-1501269-J
(Note 1) "Short term" means roughly within one month.
(Note 2) This value includes the maximum value of DO external load current (3.2A).
(Note 3) This value does not include DO external load current.
(Note 4) For the heating value of the I/O circuit, calculate with the number of points used.
(Note 5) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000
meters above sea level. Refer to the manual of drive unit for details.
(Note 6) The maximum value including the heating value of analog input circuit.
Item
Unit name Remote I/O unit
Type
FCU8-DX220/
DX230/
DX231
FCU8-DX202
FCU8-DX213/
DX213-1/
DX654/
DX654-1
FCU8-DX408 FCU8-DX409 FCU8-DX651
General
Specifications
Ambient
temperature
During
operation
0 to 58°C
During
storage
-20 to 60°C
Ambient
humidity
Long term 10 to 75% RH (with no dew condensation)
Short term
10 to 95% RH
(with no dew condensation)
(Note 1)
10 to 85% RH
(with no dew
condensation)
(Note 1)
Vibration resistance
4.9m/s
2
or less
Shock resistance
29.4m/s
2
or less
Working atmosphere No corrosive gases, dust or oil mist
Altitude
Operation/Storage: 1000 meters or less above sea level,
Transportation: 13000 meters or less above sea level
Power supply voltage 24VDC
Current consumption 3.5A (Note 2) 0.3A 0.3A (Note 3) 0.1A 0.2A 3.7A (Note 2)
Maximum
heating value
(W) 8 (Note 4) 3 6 (Note 6) 8 (Note 4)
Mass (kg) 0.4 0.2 0.3 0.8
Outline
dimension
W×H×D
(mm) 40×175×133 40×175×119 40×175×130 40×175×109 40×175×115 172×100×115