EasyManuals Logo
Home>Renesas>Microcontrollers>RX Series

Renesas RX Series User Manual

Renesas RX Series
1823 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1438 background imageLoading...
Page #1438 background image
R01UH0823EJ0100 Rev.1.00 Page 1438 of 1823
Jul 31, 2019
RX23W Group 40. SD Host Interface (SDHIa)
40.2.13 SD Error Status Register 1 (SDERSTS1)
Note 1. Command other than CMD12 or CMD52 which are automatically issued to stop data transfer.
Note 2. CMD12 or CMD52 which are automatically issued to stop data transfer.
The SDERSTS1 register indicates the CRC status token, CRC error, end bit error, and command error.
SDERSTS1
Address(es): SDHI.SDERSTS1 0008 AC58h
b31 b30 b29 b28 b27 b26 b25 b24
— — — — — — — —
Value after reset:
00000000
b23 b22 b21 b20 b19 b18 b17 b16
— — — — — — — —
Value after reset:
00000000
b15 b14 b13 b12 b11 b10 b9 b8
— CRCTK[2:0] CRCTKE RDCRCE RSPCRCE1 RSPCRCE0
Value after reset:
00100000
b7 b6 b5 b4 b3 b2 b1 b0
— — CRCLENE RDLENE RSPLENE1 RSPLENE0 CMDE1 CMDE0
Value after reset:
00000000
Bit Symbol Bit Name Description R/W
b0 CMDE0 Command Error Flag 0
0: Command index field value for a command
*1
response is error free
1: Command index field value for a command
*1
response is in error
R
b1 CMDE1 Command Error Flag 1
0: Command index field value for a command
*2
response is error free
1: Command index field value for a command
*2
response is in error (by
setting the SDCMD.CMDIDX[5:0] bits, the error that occurs by
issuing CMD12 is indicated by the CMDE0 flag)
R
b2 RSPLENE0
Response Length Error Flag
0
0: Command
*1
response length is error free
1: Command
*1
response length is in error
R
b3 RSPLENE1
Response Length Error Flag
1
0: Command
*2
response length is error free
1: Command
*2
response length is in error (by setting the
SDCMD.CMDIDX[5:0] bits, the error that occurs by issuing CMD12
is indicated by the RSPLENE0 flag)
R
b4 RDLENE Read Data Length Error Flag
0: Read data length error did not occur
1: Read data length error occurred
R
b5 CRCLENE
CRC Status Token Length
Error Flag
0: CRC status token length error did not occur
1: CRC status token length error occurred
R
b7, b6 — Reserved These bits are 0 when read. R
b8 RSPCRCE0 Response CRC Error Flag 0
0: No CRC error detected in command
*1
response
1: CRC error detected in command
*1
response
R
b9 RSPCRCE1 Response CRC Error Flag 1
0: No CRC error detected in command
*2
response
1: CRC error detected in command
*2
response (the error that occurs
for CMD12 with the setting of the SDCMD.CMDIDX[5:0] bits is
indicated by the RSPCRCE0 flag)
R
b10 RDCRCE Read Data CRC Error Flag
0: No CRC error detected in read data
1: CRC error detected in read data
R
b11 CRCTKE CRC Status Token Error Flag
0: No error detected in CRC status token
1: Error detected in CRC status token
R
b14 to b12 CRCTK[2:0] CRC Status Token Store the CRC status token value (normal value is 010b) R
b15 — Reserved This bit is 0 when read. R
b31 to b16 — Reserved These bits are undefined when read. R

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RX Series and is the answer not in the manual?

Renesas RX Series Specifications

General IconGeneral
BrandRenesas
ModelRX Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals