EasyManuals Logo
Home>Renesas>Microcontrollers>RX Series

Renesas RX Series User Manual

Renesas RX Series
1823 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
R01UH0823EJ0100 Rev.1.00 Page 240 of 1823
Jul 31, 2019
RX23W Group 11. Low Power Consumption
ï‚· Example 2: From high-speed/middle-speed operating mode to low-speed operating mode
(High-speed operation in high-speed operating mode/middle-speed operation in middle-speed operating mode)
↓
Set the frequency of each clock to lower than the maximum operating frequency for low-speed operating mode
↓
Confirm that all clock sources but the sub-clock oscillator are stopped
↓
Confirm that the SOPCCR.SOPCMTSF flag is 0 (transition completed)
↓
Set the SOPCCR.SOPCM bit to 1 (low-speed operating mode)
↓
Confirm that the SOPCCR.SOPCMTSF flag is 0 (transition completed)
↓
Low-speed operation in low-speed operating mode
(2) Switching from Low Power Consumption Mode to Normal Power Consumption Mode
ï‚· Example 1: From low-speed operating mode to high-speed/middle-speed operating mode
Low-speed operation in low-speed operating mode
↓
Confirm that the SOPCCR.SOPCMTSF flag is 0 (transition completed)
↓
Set the SOPCCR.SOPCM bit to 0 (high-speed operating mode or middle-speed operating mode)
↓
Confirm that the SOPCCR.SOPCMTSF flag is 0 (transition completed)
↓
Set the frequency of each clock to lower than the maximum operating frequency for high-speed/middle-speed operating
mode
↓
(High-speed operation in high-speed operating mode/middle-speed operation in middle-speed operating mode)
ï‚· Example 2: From middle-speed operating mode to high-speed operating mode
Middle-speed operation in middle-speed operating mode
↓
Confirm that the OPCCR.OPCMTSF flag is 0 (transition completed)
↓
Set the OPCCR.OPCM[2:0] bit to 0 (high-speed operating mode)
↓
Confirm that the OPCCR.OPCMTSF flag is 0 (transition completed)
↓
Set the frequency of each clock to lower than the maximum operating frequency for high-speed operating mode
↓
High-speed operation in high-speed operating mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RX Series and is the answer not in the manual?

Renesas RX Series Specifications

General IconGeneral
BrandRenesas
ModelRX Series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals