Bit Switches
D361 120 SM
G3-2 Switch 0A (SP No. 1-106-011)
No Function Comments
Try using a longer setting if error code
0-21 is frequent.
5 Not used Do not change the settings.
6
Reconstruction time for the first line in
receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled
by a computer, there may be a delay in
receiving page data after the local
machine accepts set-up data and sends
CFR. This is outside the T.30
recommendation. But, if this delay
occurs, set this bit to 1 to give the
sending machine more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
7 Not used Do not change the settings.
G3-2 Switch 0B- Not used (do not change the settings)
G3-2 Switch 0C- Not used (do not change the settings)
G3-2 Switch 0D - Not used (do not change the settings)
G3-2 Switch 0E - Not used (do not change the settings)
G3-2 Switch 0F - Not used (do not change the settings)
4.3.7 G4 INTERNAL SWITCHES
The G4 internal switches (SW00 to 1F) are displayed but do not change these settings.
4.3.8 G4 PARAMETER SWITCHES
The G4 parameter switches (SW00 to 0F) are displayed but do not change these settings.