SC No. Level Error Name/Error Condition/Major Cause/Solution
SC665 FFC set detection
FFC set error is detected by port lead and AD value read-out
SC665-01 D BCU-IPU connection error
• SC display
• LED blink mode correction on BCU
SC665-02 D BCU - imaging IOB connection error
SC display
SC665-03 D BCU - paper transport IOB connection error
SC display
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC669 EEPROM Communication Error
SC669-01 D EEPROM OPEN: ID error
SC669-02 D EEPROM OPEN: Channel error
SC669-03 D EEPROM OPEN: Device error
SC669-04 D EEPROM OPEN: Communication abort error
SC669-05 D EEPROM OPEN: Communication timeout error
SC669-06 D EEPROM OPEN: Operation stopped error
SC669-07 D EEPROM OPEN: Buffer full
SC669-08 D EEPROM OPEN: No error code
SC669-09 D EEPROM CLOSE: ID error
SC669-10 D EEPROM CLOSE: No error code
SC669-11 D EEPROM Data write: ID error
SC669-12 D EEPROM Data write: Channel error
SC669-13 D EEPROM Data write: Device error
Service Call 620-689