Roche Diagnostics
Operatorโ€™s Manual ยท Version 3.1 E-17
Cedex Bio System 13 ISE operation
Daily operation
Daily operation
Daily operation of the ISE unit is integrated in the daily operation of the main
instrument.
e
See Chapter 5 Daily operation.
The following table gives an overview of the tasks you might need to perform during
daily operation.
Task Steps Navigation
With wizard As individual steps
1
Starting the system 1. Switch on the system.
2
Logging on the system Overview > Logon
3
Preparing the system Start the Prepare wizard. Overview > Prepare
1. Check the external fluid containers. Overview > >
2. Check the ISE status. Overview >
3. Perform Daily Prepare Actions. Utilities > Maintenance
4
Defining orders Start the Orders wizard. Overview > Order (or Overview > STAT)
1. Identify the sample. n/a
2. Select the tests. n/a
3. Place the sample. n/a
4. Start the run.
5
Monitoring the progress n/a Overview
6
Validating results 1. View results. n/a Workplace > Result Review
2. Handle flagged results. n/a Workplace > Result Review >
... > Repeat
... > Rerun
3. Accept results. n/a Workplace > Result Review > >
Accept
7
Performing calibrations
Performing individual
calibrations
1. Start the wizard. Workplace > Calibrations >
2. Select the test. n/a
3. Prepare and place the calibrators. n/a
4. Start the calibration.
5. Validate the calibration results. Workplace > Calibrations >
6. Remove the calibrators.
Performing
all due calibrations
1. Start the wizard. Workplace > Calibrations >
2. Select all tests with due calibrations.
or
Select all tests with calibration due
within the forecast period.
n/a
3. Prepare and place the calibrators. n/a
4. Start the calibration.
5. Validate the calibration results. Workplace > Calibrations >
6. Remove the calibrators.
Table E-3 Overview of the daily operation tasks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roche Cedex Bio System and is the answer not in the manual?

Roche Cedex Bio System Specifications

General IconGeneral
BrandRoche
ModelCedex Bio System
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals