Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 21
Start Chapter 1
Extended DC-bus Configuration Example
In this example, two drive clusters in the same cabinet are connected by the
same 458…747V DC bus voltage. Kinetix 5700 accessory modules provide
connection points for the DC-bus at the end of cluster 1 and the beginning of
cluster 2. The Kinetix 5700 servo drive system is capable of up to 208 A
DC-bus current. Two accessory modules are needed when the DC-bus system
current exceeds 104 A. See Accessory Module Selection
on page 59 for more
information on the when accessory modules are required.
Figure 3 - Extended DC-bus Installation
MOD
NET
MOD
NET
MOD
NET
MOD
NET
2
1
1
4
I/O
2
1
2
1
2
1
UFB
UFB-A UFB-B
UFB-A UFB-B
D+
D-
D+
D-
D+
D-
MF-A MF-B MF-A MF-B
D+
D-
MBRK
+
-
MOD
NET
2
1
1
4
I/O
MOD
NET
2
1
1
4
I/O
MOD
NET
MOD
NET
2
1
2
1
UFB-A UFB-B
UFB-A UFB-B
D+
D-
D+
D-
MF-A MF-B MF-A MF-B
D+
D-
MOD
NET
2
1
UFB-A UFB-B
D+
D-
MF-A MF-B
D+
D-
MOD
NET
MOD
NET
2
1
2
1
UFB-A UFB-B
UFB-A UFB-B
D+
D-
D+
D-
D+
D-
MF-A MF-B MF-A MF-B
D+
D-
MOD
NET
2
1
UFB-A UFB-B
D+
D-
MF-A MF-B
D+
D-
MOD
NET
2
1
UFB-A UFB-B
D+
D-
MF-A MF-B
D+
D-
MODULE
STATUS
MOD
DC BUS
MOD
DC BUS
MODULE
STATUS
D+
D-
MF
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O-A
6
510
1
I/O-B
6
510
1
I/O
6
5
10
Kinetix 5700 Servo Drives
Cluster 1 (front view)
Bonded Cabinet
Ground Bus
Kinetix 5700 Extended Servo Drives
Cluster 2 (front view)
DC-bus Extension
Shared DC-bus and
24V DC Control Power
Circuit
Protection
1321-3R80-B
Line Reactors
(required components)
2198-P208 DC-bus Power Supplies
Single-axis
Inverter
Dual-axis
Inverters
Capacitor
Module
Extension
Module
Capacitor
Module
Extension
Module
Dual-axis Inverters
Bulletin 2198 Shared-bus
Connection System
(24V shared-bus connection
system is optional)
Magnetic Contactor
(M1) Control String
Line Disconnect
Device
324…528V AC
Three-phase
Input Power
Magnetic (M1)
Contactor
2198-DBR200-F
AC Line Filter
(required for CE)
DC-bus Extension
ATTENTION: Circuit protection can
be added after the power supply
cluster to help protect converters and
inverters from damage in the event of
a DC-bus cable short-circuit.
Circuit
Protection
IMPORTANT When two or three DC-bus power supplies are wired together in the same
drive cluster, they must all be catalog number 2198-P208.

Table of Contents

Other manuals for Allen-Bradley Kinetix 5700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Kinetix 5700 Series and is the answer not in the manual?

Allen-Bradley Kinetix 5700 Series Specifications

General IconGeneral
BrandAllen-Bradley
ModelKinetix 5700 Series
CategoryServo Drives
LanguageEnglish

Related product manuals