Rockwell Automation Publication 2198-UM002G-EN-P - February 2019 37
Start Chapter 1
Catalog Number Explanation
Kinetix 5700 drive module catalog numbers and performance descriptions.
Table 5 - Kinetix 5700 Drive Module Catalog Numbers
Kinetix 5700 Drive
Modules
Cat. No.
Module
Width
mm
Input Voltage
Continuous
Output Power
kW
Continuous Output
Current to Bus
A
DC
rms
Continuous Output
Current
A 0-pk
DC-bus Power Supply
2198-P031
2198-P070
55
324…528V AC rms,
three-phase
7
17
10.5
25.5
–
2198-P141
2198-P208
85
31
46
46.9
69.2
Regenerative
Power Supply
2198-RP088 165
324…506V AC rms,
(1)
three-phase
24 35
–
2198-RP200 275 67 100
2198-RP263
440
119 176
2198-RP312 140 207
Single-axis Inverters
2198-S086-ERS3
2198-S130-ERS3
2198-S086-ERS4
2198-S130-ERS4
85
–
29.7
44.9
–
60.8
91.9
2198-S160-ERS3 2198-S160-ERS4 100 60.1 120.2
2198-S263-ERS3
2198-S312-ERS3
2198-S263-ERS4
2198-S312-ERS4
220
90
112
212.1
271.5
Dual-axis Inverters
2198-D006-ERS3
2198-D012-ERS3
2198-D020-ERS3
2198-D032-ERS3
2198-D006-ERS4
2198-D012-ERS4
2198-D020-ERS4
2198-D032-ERS4
55
–
1.7
3.4
5.5
8.9
–
3.5
7.0
11.3
18.3
2198-D057-ERS3 2198-D057-ERS4 85 15.9 32.5
iTRAK Power Supply 2198T-W25K-ER 100 – – – 2x12.5
(1) Applies when DC-bus voltage regulation is enabled. If DC-bus voltage regulation is not enabled, the input voltage range is 324….528V AC. For more information on these two modes of operation, see
DC-bus Voltage Regulation
on page 42.
Table 6 - Accessory Module Catalog Numbers
Accessory Modules
(1)
Cat. No.
Module
Width
mm
System Current
(2)
Rated Voltage Capacitance
Capacitor Module 2198-CAPMOD-2240
55 104 A 458…747V DC, nom
2240 μF
Extension Module 2198-CAPMOD-DCBUS-IO
–
DC-bus Conditioner Module 2198-DCBUSCOND-RP312
(1) Combination of any two accessory modules increases system current up to 208 A. However, modules must be mounted side-by-side and joined by two flexible bus-bars.
(2) Flexible bus-bars are included with only the 2198-CAPMOD-DCBUS-IO extension module. So, if you have two capacitor modules, two DC-bus conditioner modules, or a capacitor module and DC-bus
conditioner module mounted side by side, you must order the 2198-KITCON-CAPMOD2240 or 2198-KITCON-DCBUSCOND connector set separately.