Measurement Process
FQ2-S4 User’s Manual
21
1
Introduction
1-2 Measurement Process
This section describes the basic flow of the measurement process.
• The measurement is started by inputting a trigger signal from an external
device.
• Images are taken according to the trigger.
• The image is measured to see if it matches the configured settings.
• You can also perform calculations based on the measurement results from
inspection items.
• The overall judgement of all inspection items are output using OR logic.
• You can output detailed measurement result from the inspection items.
• Measurement data and image data can be logged in memory in the Sensor or
in an SD card.
Trigger input
Take image
Measurement
Output
Logging