RX23W Group 23. Multi-Function Timer Pulse Unit 2 (MTU2a)
(22) Operation When Error Occurs in Complementary PWM Mode and Operation is Restarted in
PWM Mode 1
Figure 23.137 shows a case in which an error occurs in complementary PWM mode and operation is restarted in PWM
mode 1 after re-setting.
Figure 23.137 Error Occurrence in Complementary PWM Mode, Recovery in PWM Mode 1
(1) to (10) are the same as in Figure 23.136.
(11) Set PWM mode 1 (MTU output goes low).
(12) Initialize the pins with the TIOR register. (In PWM mode 1, a waveform is not output on the MTIOCnB
(MTIOCnD) pins. If a level is to be output, make the required general output port settings in the I/O port’s port
direction register (PDR) and port output data register (PODR).)
(13) Use the MPC and the port mode register (PMR) for the I/O port to set up MTU output.
(14) Restart operation by setting the TSTR register.
(1)
Reset
MTU module output
(2)
TOCR
(3)
TMDR
(CPWM)
(4)
TOER
(1)
(6)
TSTR
(1)
(7)
Match
(8)
Error
occurs
(9)
Port
output
(10)
TSTR
(0)
(11)
TMDR
(PWM1)
(12)
TIOR
(1 init
0 out)
(14)
TSTR
(1)
MTIOC3A
MTIOC3B
MTIOC3D
PORT output
Pxx
Pxx
Pxx
(5)
MPC
(MTU)
(13)
MPC
(MTU)
Not initialized (MTIOC3B)
Not initialized (MTIOC3D)
Hi-Z
Hi-Z
Hi-Z