Property Version
Line voltage 200 V … 240 V 1 AC, ±10 %
Output voltage 0 V 3 AC … input voltage
Input frequency 50 Hz … 60 Hz, ±10%
Output frequency 0 … 550 Hz
Relative supply short-circuit
power
RSC ≥ 25
Power factor λ > 0.9
Overvoltage category to IEC/
EN 61800-5-1
● Up to 2000 m: The converter insulation is designed for surge voltages of overvoltage
category III.
● More than 2000 m: The surge voltages must be limited to values of overvoltage category
II, using an isolation transformer, for example.
Pulse frequency 8 kHz
Short-circuit current rating
(SCCR) and branch protection
≤ 65 kA rms
Branch protection and short-circuit strength according to UL and IEC
Protective devices (https://support.industry.siemens.com/cs/ww/en/view/
109748999)
Degree of protection according
to EN 60529
IP20 Must be installed in a control cabinet
Electronics power supply 24 V DC, -15% … +20%, I
max
= 1.6 A (PELV or SELV)
Control mode Servo control
Protection functions Ground fault protection, output short-circuit protection, overvoltage/undervoltage protection,
I2t detection, IGBT overtemperature protection
Technical data of the digital inputs
Type High-speed digital inputs
for probe or reference
marks
Fail-safe input
(F-DI)
Digital input for monitoring
the temperature of an ex‐
ternal braking resistor
Number 2 (DI 0, DI 1) 1 (DI 2 and DI 3) 1 (DI 4)
● Low level
-30 V ... +5 V
and ≤ 2 mA
-30 V ... +5 V
and ≤ 2 mA
-30 V ... +5 V
and ≤ 2 mA
● High level
15 V ... 30 V 15 V ... 30 V 15 V ... 30 V
● Current consumption
6 mA 5 mA 6 mA
● Delay time, typ. L → H
5 µs 50 μs 5 µs
● Delay time, typ. H → L
50 μs 100 µs 50 μs
● Electrical isolation
No Yes No
Conductor cross section, max. 1.5 mm² 1.5 mm² 1.5 mm²
Technical specifications
8.2 Technical specifications of the converter
SINAMICS S210 servo drive system