EasyManuals Logo
Home>Siemens>Servo Drives>SINAMICS S210

Siemens SINAMICS S210 User Manual

Siemens SINAMICS S210
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #204 background imageLoading...
Page #204 background image
8.2.3 General data, converter
Property Version
Line voltage 200 V … 240 V 1 AC, ±10 %
Output voltage 0 V 3 AC … input voltage
Input frequency 50 Hz … 60 Hz, ±10%
Output frequency 0 … 550 Hz
Relative supply short-circuit
power
RSC ≥ 25
Power factor λ > 0.9
Overvoltage category to IEC/
EN 61800-5-1
Up to 2000 m: The converter insulation is designed for surge voltages of overvoltage
category III.
More than 2000 m: The surge voltages must be limited to values of overvoltage category
II, using an isolation transformer, for example.
Pulse frequency 8 kHz
Short-circuit current rating
(SCCR) and branch protection
≤ 65 kA rms
Branch protection and short-circuit strength according to UL and IEC
Protective devices (https://support.industry.siemens.com/cs/ww/en/view/
109748999)
Degree of protection according
to EN 60529
IP20 Must be installed in a control cabinet
Electronics power supply 24 V DC, -15% … +20%, I
max
= 1.6 A (PELV or SELV)
Control mode Servo control
Protection functions Ground fault protection, output short-circuit protection, overvoltage/undervoltage protection,
I2t detection, IGBT overtemperature protection
Technical data of the digital inputs
Type High-speed digital inputs
for probe or reference
marks
Fail-safe input
(F-DI)
Digital input for monitoring
the temperature of an ex‐
ternal braking resistor
Number 2 (DI 0, DI 1) 1 (DI 2 and DI 3) 1 (DI 4)
Low level
-30 V ... +5 V
and ≤ 2 mA
-30 V ... +5 V
and ≤ 2 mA
-30 V ... +5 V
and ≤ 2 mA
High level
15 V ... 30 V 15 V ... 30 V 15 V ... 30 V
Current consumption
6 mA 5 mA 6 mA
Delay time, typ. L → H
5 µs 50 μs 5 µs
Delay time, typ. H → L
50 μs 100 µs 50 μs
Electrical isolation
No Yes No
Conductor cross section, max. 1.5 mm² 1.5 mm² 1.5 mm²
Technical specifications
8.2 Technical specifications of the converter
SINAMICS S210 servo drive system
202 Operating Instructions, 12/2017, A5E41702836B AA

Table of Contents