Reaction: NONE
Acknowledge: NONE
Cause: The rotating measurement is activated. For the rotating measurement, the motor can accelerate up to the maximum speed
and with maximum torque. Only the parameterized current limit (p0640) and the maximum speed (p1082) are effective.
The behavior of the motor can be influenced using the direction inhibit (p1959.14, p1959.15) and the ramp-up/ramp-down
time (p1958).
The rotating measurement is carried out at the next switch-on command.
Remedy: Not necessary.
The alarm is automatically withdrawn after the rotating measurement has been successfully completed or for the setting
p1960 = 0.
Note:
If a POWER ON or a warm restart is performed with motor data identification selected, the motor data identification request
will be lost. If motor data identification is required, it will need to be selected again manually following ramp-up.
F07990 Drive: Incorrect motor data identification
Message value: %1
Drive object: All objects
Reaction: OFF2 (NONE, OFF1)
Acknowledge: IMMEDIATELY
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 479