Reaction: NONE
Acknowledge: NONE
Cause: A configuration of motor holding brake and SBC was detected that is not practical.
The following configurations can result in this message:
- "No motor holding brake available" (p1215 = 0) and "SBC" enabled (p9602 = 1).
Note:
SBC: Safe Brake Control
Remedy: Check the parameterization of the motor holding brake and SBC and correct.
See also: p1215, p9602
Reaction upon F: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F: IMMEDIATELY
Reaction upon N: NONE
Acknowl. upon N: NONE
A01637 (F, N) SI: Safety password not assigned
Message value: -
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: Safety Integrated is parameterized and enabled. However, a valid safety password has still not been entered.
See also: r9767 (SI safety password status)
Remedy: - assign a valid safety password.
- carry out data save.
Reaction upon F: Servo: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F: IMMEDIATELY (POWER ON)
Reaction upon N: NONE
Acknowl. upon N: NONE
A01638 (F, N) SI: Safety password entered
Message value: -
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: A valid safety password has been entered. It is possible to change safety parameters in the safety commissioning mode.
See also: r9767 (SI safety password status)
Remedy: Not necessary.
This alarm is automatically withdrawn with "Delete password" (e.g. after exiting the web server - or after a Power on). The
password remains assigned.
Reaction upon F: Servo: NONE (OFF1, OFF2, OFF3)
Acknowl. upon F: IMMEDIATELY (POWER ON)
Reaction upon N: NONE
Acknowl. upon N: NONE
F01640 (N, A) SI P1 (CU): component replacement identified and acknowledgment/save required
Message value: Fault cause: %1
Drive object: All objects
Reaction: NONE
Acknowledge: IMMEDIATELY
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system