Note
Setting ranges for p0210 as a function of the rated power unit voltage:
U_rated = 400 V:
- p0210 = 380 ... 480 V (AC/AC), 510 ... 720 V (DC/AC)
U_rated = 500 V:
- p0210 = 500 ... 600 V (AC/AC), 675 ... 900 V (DC/AC)
U_rated = 660 ... 690 V:
- p0210 = 660 ... 690 V (AC/AC), 890 ... 1035 V (DC/AC)
U_rated = 500 ... 690 V:
- p0210 = 500 ... 690 V (AC/AC), 675 ... 1035 V (DC/AC)
The precharging switch-in threshold for the DC link voltage (Vdc) is calculated from p0210:
Vdc_pre = p0210 * 0.82 * 1.35 (AC/AC)
Vdc_pre = p0210 * 0.82 (DC/AC)
The undervoltage thresholds for the DC link voltage (Vdc) are calculated from p0210 as a function of the rated power
unit voltage:
U_rated = 400 V:
- U_min = p0210 * 0.78 (AC/AC) > 330 V, p0210 * 0.60 (DC/AC) > 380 V
U_rated = 500 V:
- U_min = p0210 * 0.76 (AC/AC) > 410 V
U_rated = 660 ... 690 V:
- U_min = p0210 * 0.82 (AC/AC) > 565 V, p0210 * 0.63 (DC/AC) > 650 V
U_rated = 500 ... 690 V:
- U_min = p0210 * 0.82 (AC/AC) > 420 V, p0210 * 0.63 (DC/AC) > 480 V
r0302[0] motor code DRIVE-CLiQ
Data type: Unsigned16 P group: Motor
Description: Displays the number of the motor with DRIVE-CLiQ
When the drive powers up, the motor code is read out the motor.
For r0302 = 0, the motor was not identified.
r0304[0] Rated motor voltage
Data type: FloatingPoint32 P group: Motor
Description: Displays the rated motor voltage.
r0305[0] Rated motor current
Data type: FloatingPoint32 P group: Motor
Description: Displays the rated motor current.
r0307[0] Rated motor power
Data type: FloatingPoint32 P group: Motor
Description: Displays the rated motor power.
r0311[0] Rated motor speed
Data type: FloatingPoint32 P group: Motor
Description: Displays the rated motor speed.
r0312[0] Rated motor torque
Data type: FloatingPoint32 P group: Motor
Description: Displays the rated motor torque.
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA 235