Acknowledge: IMMEDIATELY
Cause: The connection to one of the heat sink temperature sensors in the HF Damping Module is interrupted.
Fault value (r0949, interpret hexadecimal):
Bit 0: HF Damping Module
Bit 1: HF Choke Module
Remedy: Contact the manufacturer.
Note:
HF Choke Module (reactor module)
HF Damping Module
F37013 HF Damping Module: Heat sink temperature sensor short-circuit
Message value: %1
Drive object: All objects
Reaction: OFF1 (OFF2)
Acknowledge: IMMEDIATELY
Cause: The heat sink temperature sensor in the HF Damping Module is short-circuited.
Fault value (r0949, interpret hexadecimal):
Bit 0: HF Damping Module
Bit 1: HF Choke Module
Remedy: Contact the manufacturer.
Note:
HF Choke Module (reactor module)
HF Damping Module
F37024 HF Damping Module: Overtemperature thermal model
Message value: -
Drive object: All objects
Reaction: OFF2
Acknowledge: IMMEDIATELY
Cause: The temperature difference between the heat sink and chip has exceeded the permissible limit value.
- the permissible load duty cycle was not maintained.
- insufficient cooling, fan failure.
- overload.
- ambient temperature too high.
- pulse frequency too high.
See also: r0037
Remedy: - adapt the load duty cycle.
- check whether the fan is running.
- check the fan elements.
- check whether the ambient temperature is in the permissible range.
- check the motor load.
- reduce the pulse frequency if this is higher than the rated pulse frequency.
F37025 HF Damping Module: Chip overtemperature
Message value: %1
Drive object: All objects
Reaction: OFF2
Acknowledge: IMMEDIATELY
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
710 Operating Instructions, 12/2017, A5E41702836B AA