Dependency: See also: F07093
Note
If, within this time, no setting values can be determined, then the drive is shut down with the corresponding fault.
r5600 Pe energy-saving mode ID
Data type: Integer16 P group: Communications
Description: Displays the PROFIenergy mode ID of the effective energy-saving mode.
Value: 0: POWER OFF
2: Energy-saving mode
240: Operation
255: Ready
Note
Pe: PROFIenergy profiles
p5611 Pe energy-saving properties general
Changeable: T Data type: Unsigned32 P group: Communications
Min: - Max: - Def: 0000 bin
Description: Sets the general properties for energy-saving.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Inhibit PROFIenergy control commands Yes No -
Note
Pe: PROFIenergy profiles
r8936[0...1] PN cyclic connection state
Data type: Integer16 P group: -
Description: Displays the state of the cyclic PROFINET connections.
Value: 0: Interrupted
1: Not connected
2: Connection starts to be established
3: Module information expected
4: Module information received
5: Module address expected
6: Module address received
7: Parameterization data expected
8: Parameterization data received
9: Evaluate parameterization data
10: Connection being established completion expected
11: Configured controller RUN expected
12: Configured controller STOP
13: Configured controller RUN
Index: [0] = Controller 1
[1] = Controller 2
Parameters
12.2 List of parameters