Remedy: If required, return the master control and repeat the operation.
Reaction upon A: NONE
Acknowl. upon A: NONE
A01590 (F) Drive: Motor maintenance interval expired
Message value: Fault cause: %1 bin
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: The selected service/maintenance interval for this motor was reached.
Alarm value (r2124, interpret decimal):
Motor data set number.
Remedy: carry out service/maintenance and reset the service/maintenance interval (p0651).
Reaction upon F: NONE
Acknowl. upon F: IMMEDIATELY
F01600 SI P1 (CU): STOP A initiated
Message value: %1
Drive object: All objects
Reaction: OFF2
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The drive-integrated "Safety Integrated" function in monitoring channel 1 has detected a fault and initiated a STOP A (STO
via the safety switch-off signal path of monitoring channel 1).
- forced checking procedure (test stop) of the safety switch-off signal path of monitoring channel 1 unsuccessful.
- subsequent response to fault F01611 (defect in a monitoring channel).
Fault value (r0949, decimal interpretation):
0: Stop request from monitoring channel 2.
1005: STO active although STO not selected and there is no internal STOP A present.
1010: STO inactive although STO is selected or an internal STOP A is present.
9999: Subsequent response to fault F01611.
Remedy: - select Safe Torque Off and de-select again.
- replace drive.
For fault value = 9999:
- carry out diagnostics for fault F01611.
Note:
SI: Safety Integrated
STO: Safe Torque Off
F01611 (A) SI P1 (CU): Defect in a monitoring channel
Message value: %1
Drive object: All objects
Reaction: NONE (OFF1, OFF2, OFF3)
Acknowledge: IMMEDIATELY (POWER ON)
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system